Power | 3KW/4KW/5KW/6KW |
Voltage | 100~600V |
Size | 360×420×125 Mm |
Certificate | EN62109-1, EN62109-2 NB/T32004, AS3100, AS4777, EN 61000-6-2, EN 61000-6-3 , IEC 62116,2014 ,IEC 61727,2004 ,IEC 60068-2-1,2007 |
Lead Time | 7 DAYS |
Payment | T/T,PAYAPL,WESTERN UNION,L/C |
Warranty | 5/10 YEARS |
Recommended product: BSM3000/5000/6000-B2 This type of inverter is well protected and suitable for outdoor use and is easy to install.
Items |
BSM3000-B2 |
BSM4000-B2 |
BSM5000-B2 | BSM6000-B2 |
DC Input |
||||
Max. PV input voltage |
600Vdc |
|||
Rated PV voltage |
360Vdc |
|||
Max. PV input current |
22A(2×11A) |
|||
No. of MPPTs |
2 |
|||
No.of PV strings per MPPT |
1/1 |
|||
MPPT voltage range |
100Vdc ~500Vdc |
|||
Starting voltage |
120Vdc |
|||
AC Output |
||||
Rated AC output power |
3.0kW |
4.0kW |
5.0kW |
6.0kW |
Max. output power |
3.3kVA |
4.4kVA |
5.5kVA |
6.0kVA |
Rated AC output voltage |
220V/230Vac |
|||
Rated output current |
13.0A |
17.4A |
21.7A |
26.0A |
Max. output current |
14.3A |
19.1A |
23.9 A |
26.0 A |
Rated grid frequency |
50/60Hz |
|||
Grid frequency range |
45~55Hz/55~65Hz |
|||
Power factor |
>0.99 full load |
|||
Adjustable power factor |
0.8 (leading) ~ 0.8 (lagging) |
|||
THDi |
<3% (rated power) |
|||
Efficiency |
||||
Max. efficiency |
98.10% |
98.30% |
||
European efficiency |
97.70% |
97.90% |
||
General |
||||
Dimensions (W×H×D) |
360×420×125 mm |
|||
Weight |
12.6kg |
|||
IP grade |
IP65 |
|||
Noise level |
≤25 dB |
|||
Night power consumption |
<1W |
|||
Cooling type |
Natural cooling |
|||
Altitude |
4000m (>2000m derating ) |
|||
Operating temperature |
-40ºC~60ºC (>45ºC derating) |
|||
Relative humidity |
0~95% |
|||
Display |
LCD display + LED indicator |
|||
Communication |
RS485/WiFi (optional)/GPRS (optional)/DRM(Australia) |
|||
DC terminal |
MC4 Terminal |
|||
AC terminal |
Plug and play connector |
|||
Installation method |
Wall-mounted |
|||
Standard |
EN62109-1, EN62109-2 NB/T32004, AS3100, AS4777, EN 61000-6-2, EN 61000-6-3 , IEC 62116:2014 ,IEC 61727:2004 ,IEC 60068-2-1:2007 |
|||